Lenovo ThinkSystem DA240 Reference page 131

Enclosure and compute node
Table of Contents

Advertisement

• FQXSPPU0003N: [ProcessorElementName] has Failed with IERR.
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0042
User Action:
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or UEFI firmware update that applies
to this processor error.
2. Reboot system.
3. If the problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPPU0004M: [ProcessorElementName] has Failed with FRB1/BIST condition.
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0044
User Action:
Complete the following steps:
1. If the system board or firmware has been updated, check the Lenovo support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. If the problem persists, collect Service Data log.
3. Contact Lenovo Support.
• FQXSPPU0007N: CPU voltage mismatch detected on [ProcessorElementName].
This message is for the use case when an implementation has detected a CPU voltage mismatch with the
socket voltage.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0050
User Action:
Complete the following steps:
1. Verify that the processors are installed in the correct sockets according to the service information for
this product. If not, correct that problem.
.