Lenovo ThinkSystem DA240 Reference page 143

Enclosure and compute node
Table of Contents

Advertisement

1. Check the Support Portal (http://support.lenovo.com/) for service bulletins and TECH tips and
firmware update related to your drive.
2. Check for any other RAID-related error.
3. Replace the drive.
• FQXSPSD0003G: Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Replace drive 0 at the next maintenance period.
• FQXSPSD0003I: Hot Spare enabled for [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
• FQXSPSD0005I: Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
• FQXSPSD0005L: Array [ComputerSystemElementName] is in critical condition.
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0174
User Action:
.
Chapter 3