4. Reseat all DIMMs ensuring that DIMMs are installed in the correct population sequence, according to
the service information for this product.
5. Clear CMOS memory. Note that all firmware settings will revert to the defaults.
6. Reflash UEFI firmware.
7. If the problem persists, collect Service Data logs.
8. Contact Lenovo Support.
• FQXSFMA0006I: [arg1] DIMM [arg2] has been detected, the DIMM serial number is [arg3].
Severity: Info
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does not have qualified memory
installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Please contact your Local Sales Representative or Authorized Business Partner to order qualified
memory to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
• FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]
Severity: Info
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does not have qualified memory
installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Please contact your Local Sales Representative or Authorized Business Partner to order qualified
memory to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
• FQXSFMA0008I: DIMM [arg1] POST memory test failure has been recovered. [arg2]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0008M: DIMM [arg1] has failed the POST memory test. [arg2]
Severity: Error
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
188