Lenovo ThinkSystem DA240 Reference page 21

Enclosure and compute node
Table of Contents

Advertisement

• 02010909: SMM2 Brd 1.2V: Voltage sensor, critical event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 1.2V power rail is higher than upper critical threshold.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 33622281
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201090A: SMM2 Brd 2.5V: Voltage sensor, critical event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 2.5V power rail is higher than upper critical threshold.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 33622282
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201090B: SMM2 Brd 3.3V: Voltage sensor, critical event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 3.3V power rail is higher than upper critical threshold.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 33622283
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201090C: SMM2 Brd 5V: Voltage sensor, critical event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 5V power rail is higher than upper critical threshold.
Severity: Error
Alert Category: System - SMM2 system event
.
17
Chapter 2
SMM2 events

Advertisement