Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112696
User Action:
1. Re-configure the enclosure power capping setting from web GUI or IPMI command.
2. If the event persists, check the power capping setting and status of populated compute nodess to
identify fault compute node(s), reset the BMC on indicated compute node(s).
3. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
4. If the event persists, replace the indicated compute node. (Service technician only)
5. If the event persists, please consult with technical service.
• 180702F9: Encl PMax Exceed: Chassis, transition to Critical from less severe was asserted.
For the populated nodes which are powered on, the summary of maximum inventory power are above the
available power bank.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112697
User Action:
Please contacts with service technician to upgrade power supplies to provide sufficient power bank.
• 180702FA: Encl PMin Exceed: Chassis, transition to Critical from less severe was asserted.
For the populated nodes which are powered on, the summary of minimum inventory power are above the
available power bank.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112698
User Action:
Please contacts with the service technician to upgrade power supplies to provide sufficient power bank.
• 180708EF: PSU ZOutput Fail: Chassis, Informational was asserted.
The enclosure is fail to activate zero output function.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 403114223
User Action:
Information only; no action is required.
• 180708F2: Encl Vtl Reseat: Chassis, Informational was asserted.
User performs the enclosure level virtual reseat to power cycle the whole enclosure.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 403114226
User Action:
Information only; no action is required.
• 180708F3: Thermal Acoustic: Chassis, Informational was asserted.