This message is for the use case when an implementation has detected a Managed Element is Absent.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0392
User Action:
Information only; no action is required
• FQXSPPU0001N: An Over-Temperature Condition has been detected on [ProcessorElementName].
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0036
User Action:
Complete the following steps until the problem is solved:
1. Check the event log of XClarity Controller and SMM2 Web GUI for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the enclosure is not obstructed and that fillers are in
place, clean and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the processor 1 heat sink is securely installed.
5. Make sure that the processor 1 heat sink is installed correctly and the thermal interface is correctly
applied.
6. (Trained technician only) Back up data and remove the existing components which have already been
installed in the defective node. Then, replace the defective node tray and re-install the components.
• FQXSPPU0002G: The Processor [ProcessorElementName] is operating in a Degraded State.
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0038
User Action:
Complete the following steps:
1. Check the event log of XClarity Controller for any fan- or cooling-related issues or power-related
issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place, clean and correctly installed.