• 2104011E: Node 3 BMC: Slot Or Connector, Predictive Failure asserted was asserted.
The BMC on indicated compute node has loss response over 1 minute, the fans are ramped up to prevent
the compute node from potential thermal conditions.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 553910558
User Action:
Information only; no action is required.
• 2104011F: Node 4 BMC: Slot Or Connector, Predictive Failure asserted was asserted.
The BMC on indicated compute node has loss response over 1 minute, the fans are ramped up to prevent
the compute node from potential thermal conditions.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 553910559
User Action:
Information only; no action is required.
• 21050128: Node 1 Inventory: Slot Or Connector, Limit Exceeded was asserted.
The BMC on indicated compure node reports an invalid inventory power whose minimum value higher
than the maximum value.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 553976104
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, reset BMC to default setting to trigger inventory power calculation again.
3. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
4. If the event persists, replace the indicated compute node. (Service technician only)
5. If the event persists, please consult with technical service.
• 21050129: Node 2 Inventory: Slot Or Connector, Limit Exceeded was asserted.
The BMC on indicated compure node reports an invalid inventory power whose minimum value higher
than the maximum value.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 553976105
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, reset BMC to default setting to trigger inventory power calculation again.
3. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
4. If the event persists, replace the indicated compute node. (Service technician only)
5. If the event persists, please consult with technical service.