Putting Into Service; Air Supply - Stanley 07287 Instruction And Service Manual

Hydro-pneumatic power tool
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
O R I G I N A L I N S T R U C T I O N

4. PUTTING INTO SERVICE

IMPORTANT - READ THE SAFETY RULES ON PAGE 4 & 6 CAREFULLY BEFORE PUTTING INTO SERVICE.
Before Use
Select relevant size nose equipment and install.
Connect the placing tool to the air supply. Test pull and return cycles by depressing and releasing the trigger 6.
CAUTION - Correct supply pressure is important for proper function of the installation tool. Personal injury or
damage to equipment may occur without correct pressures. The supply pressure must not exceed that listed in
the placing tool specifi cation

4.1 AIR SUPPLY

All tools are operated with compressed air. The pressure regulator in the cabinet is set to an optimum pressure of 5.25 bar.
Regardless of the air inlet pressure, the pressure gauge in the cabinet will show 5.25 bar maximum. The pressure regulator
in the cabinet must not be adjusted under any circumstances. In addition, we recommend the use of external pressure
regulators and automatic oiling/fi ltering systems on the main air supply. These should be fi tted within 3 meters of the tool
(see diagram below) to ensure maximum tool life and minimum tool maintenance.
CAUTION - The pressure regulator in the cabinet is set to 5.25 bar.
CAUTION - The pressure regulator must not be adjusted under any circumstances.
CAUTION - The safety valve in the cabinet is set to 5.25 - 5.30 bar.
CAUTION - The safety valve must not be adjusted under any circumstances.
Air supply hoses should have a minimum working eff ective pressure rating of 150% of the maximum pressure produced
in the system or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and
should be armoured where operating conditions may result in hoses being damaged. All air hoses MUST have a minimum
bore diameter of 6.4 mm or 1/4 inch.
Read servicing daily details page 15.
STOP COCK
STOP CLOCK
(USED DURING MAINTENANCE
(USED DURING MAINTENANCE OF
OF FILTER / REGULATOR OR
FILTER / REGULATOR OR
LUBRICATION UNITS
LUBRICATION UNITS
LUBRICATOR PRESSURE REGULATOR
LUBRICATOR PRESSURE REGULATOR
AND FILTER
AND FILTER (DRAIN DAILY)
(DRAIN DAILY)
E N G L I S H
TAKE OFF POINT FROM
TAKE OFF POINT
MAIN SUPPLY
FROM MAIN SUPPLY
MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
DRAIN POINT
9

Advertisement

Table of Contents
loading