Monitor-to-Monitor Data Copy — COPY Menu
Overview
When multiple monitors are connected via their serial
remote ports, data can be shared between the monitors
by data copy. The data copy from one monitor to
another is accomplished with the COPY menu.
Structure of the COPY Menu [E]
Main menu
Level 1
MONITOR ADDRESS E1
COPY E
Constituent Menus of the COPY Menu
This section describes the functions of the constituent
menus of the COPY menu.
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
[E] COPY menu
Select the copy source monitor.
MONITOR ADDRESS: Enter the address number.
÷ [E1]
52
Level 2
ALL
CONTROL PRESET
CONTROL TEMP
SET UP
[E1] MONITOR ADDRESS menu
Select the data to be copied. ÷ Copy is carried out.
ALL: Copy data for all menu settings.
CONTROL PRESET: Copy the data for the
CONTROL PRESET ADJ menu settings.
COLOR TEMP: Copy the data for the COLOR
TEMP ADJ menu settings.
SET UP: Copy the data for the SET UP menu
settings.
Need help?
Do you have a question about the TRINITRON BVM-20F1U, BVM-20F1E, BVM-20E1U, BVM-20E1E, BVM-14F1U, BVM-14F1E, BVM-14E1U, BVM-14E1E, BVM-14F5U, BVM-14F5E, BVM-14E5 and is the answer not in the manual?