Specifications

General
System
525 lines, 60 fields per second
interlaced
625 lines, 50 fields per second
interlaced
CRT
Super fine pitch Trinitron
BVM-20F1U/20F1E/20E1U/
20E1E
Aperture grille pitch: 0.3 mm
(BVM-20F1U/20F1E) or
0.25 mm (BVM-20E1U/
20E1E), 90 degree deflection,
30.6 mm diameter in-line gun.
Effective picture size:
387 × 291 mm (15
11
1
483 mm (19
size)
CRT protection: EHT (extremely
high tension) protection type
Warm-up time: approx. 30 minutes
Anode voltage: 27 kV with no
beam current
Nominal chromaticity coordinates:
SMPTE phosphor (BVM-20F1U/
R
G
B
Error: less than ±0.005
EBU phosphor (BVM-20F1E/20E1E)
R
G
B
Error: less than ±0.005
BVM-14F1U/14F1E/14E1U/
14E1E//14F5U/14F5E/14E5U/
14E5E
Aperture grille pitch: 0.25 mm
(BVM-14F1U/14F1E/14F5U/
14F5E) or 0.22 mm (BVM-
14E1U/14E1E/14E5U/14E5E),
90-degree deflection, 29.4 mm
diameter in-line gun.
×
1
/
4
/
inches) (w/h)
2
1
/
inches) (diagonal
8
20E1U)
x
y
0.630
0.340
0.310
0.595
0.155
0.070
x
y
0.640
0.330
0.290
0.600
0.150
0.060
Effective picture size:
267 × 200 mm (10
7
7
/
331 mm (13
size)
CRT protection: EHT (extremely
high tension) protectiontype
Warm-up time: approx. 30 minutes
Anode voltage: 25 kV with no
beam current
Nominal chromaticity coordinates:
SMPTE phosphor (BVM-14F1U/
R
G
B
EBU phosphor (BVM-14F1E/14E1E)
R
G
B
Power requirements
100 to 240 V AC, 10%, 50/60 Hz
Power consumption
BVM-20F1U/20F1E/20E1U/
20E1E: 120 W
When an optional adaptor is
installed: 200 W
BVM-14F1U/14F1E/14E1U/
14E1E: 110 W
When an optional adaptor is
installed: 145 W
BVM-14F5U/14F5E/14E5U/
14E5E: 110 W
When an optional adaptor is
installed: 175 W
Peak inrush current
(1) Power ON, current probe method:
55A (240V) (BVM-20F1E/20E1E/14F5E/
14E5E/14F1E/14E1E)
(2) Hot switching inrush current, measured in
accordance with European standard
EN55103-1: 50A (230V) (BVM-20F1E/
20E1E), 38A (230V) (BVM-14F5E/14E5E/
14F1E/14E1E)
×
5
/
8
inches) (w/h)
8
1
/
inches) (diagonal
8
14E1U)
x
y
0.630
0.340
0.310
0.595
0.155
0.070
x
y
0.640
0.330
0.290
0.600
0.150
0.060