Sensor Zero trim by HHT

Sensor Zero trim by Hand Held T erminal is availa ble. Please refer to th e device manual for the right
operations.

Sensor Zero trim by PC

Sensor Zero trim by P C is available using dedicated Software. ABB can provide the references and t he
Software. Please refer to the Software instructions for the right operations.

Sensor Low Trim

The Sensor Low trim provide the correct offset of the factory characterization. The transmitter shall be within
five percent of the true value.
If the PV scaling has been performed the sensor trim is not available.

Sensor Low trim by Digital LCD Integral Display

Set the transmitter applie d pressure as for Low trim value and wait for a stable value. Navigate the Digital
LCD Integral Display menu, select
values is available. To modify select
confirm with
Next.
Repeat the operation for the seven digits and confirm with
The first digit is the si gn (- or space for +) and one digit can be the dot. The Maximum and Minimum values
are indicated on the Display as reference.
Digital LCD Integral Display Keys sequence to Low Trim the sensor: 6 – 1 – 1 – Edit

Sensor Low trim by HHT

Sensor Low trim by Ha nd Held Terminal is available. Please refer to the
operations.

Sensor Low trim by PC

Sensor Low trim by PC i s available using dedicated Software. ABB can provide the references and the
Software. Please refer to the Software instructions for the right operations.

Sensor High trim

Adjustment of the Sensor high trim value provides a slope correction to the characterization curve based on
the low trim value.
If the PV scaling has been performed the sensor trim is not available.

Sensor High trim by Digital LCD Integral Display

Set the transmitter applie d pressure as for High trim value and wait for a stable value. Navigate the Digital
LCD Integral Display men u, select
values is available. To modify select
confirm with
Next.
Repeat the operation for the seven digits and confirm with
The first digit is the sign (- or space for +) and one digit can be the dot.
Note: the Maximum and Minimum values are indicated on the Display as reference.
Digital LCD Integral Display Keys sequence to High Trim the sensor: 6 – 1 – 2 – Edit

Sensor High trim by HHT

Sensor High trim by Hand Held T erminal is availa ble. Please refer to th e device manual for the right
operations.
Reset the PV scaling before continuing the Sensor trim.
Calibrate
>
Edit
then scroll the d esired value with the u p and down keys and
Reset the PV scaling before continue the Sensor trim.
Calibrate
>
Edit
then scroll the d esired value with the u p and down keys and
Sensor Trim
>
Lower Sensor Trim
Sensor Trim
>
Upper Sensor Trim
364Ax-Gx Instruction Manual
and the Sensor Lo w trim
OK.
device manual for the right
and the Senso r High trim
OK.