Hart Configuration; Basic Configuration Functions; Set The Damping; Set The Damping Configuration By Digital Lcd Integral Display - ABB 364G Series Manual

Table of Contents

Advertisement

HART Configuration

Basic Configuration Functions

This chapter describes some additional functions provided by th e 364xS mo dels which are unique to t he
2600T pressure transmitter family.

Set the Damping

When damping different from default value is needed, it is possible to set its value in seconds following one
of the methods described in the next paragraphs.

Set the Damping configuration by Digital LCD Integral Display

Navigate the Digital LCD Integral Display menu, select
the up and down keys and confirm with
Digital LCD Integral Display Keys sequence to set the Damping: 2 – 3

Set the Damping configuration by CoMeter

Damping configuration by CoMeter is available wit h the 695 Field Indicator. Please refer to the device
manual for the appropriate operations.

Set the Damping configuration by HHT

Damping configuration by Hand Held Terminal is availabl e. Please refer to the device manual for the
appropriate operations.

Set the Damping configuration by PC

Damping configuration by PC is available using dedicated Software. ABB can provide the references and the
Software. Please refer to the Software instructions for the appropriate operations.

Set the Units

To monitor t he process using the ap propriate units follow on e of the method s described in the next
paragraphs.

Set the Units by Digital LCD Integral Display

To change the unit in the Digital LCD Integral Display
Navigate the Digital LCD Integral Display menu, select
the possible Engineering variables will be available. To select the type, push
down keys; confirm with
Pressure
Temperature
Mass & Volume
Level
Other
Custom Unit
The in-use unit for the ty pe will be available. To modify select
following tables) with the up and down keys and confirm with
Units for Pressure variable
mbar
millibar
2
g/cm
grams per square centimeter
2
Kg/cm
kilo grams per square centimeter
Pa
pascal
kPa
kilopascal
torr
torr
atm
atmosphere
MPa
Megapascal
inH2O°C
inches of water at 4 degrees Celsius
OK.
OK.
Device Config
> Damping, set the desired value with
Display
>
Display Settings
Edit
then scroll the desired unit (see the
OK.
mmH2O°C
millimeter of water at 4 degrees Celsius
inH2O°F
inches of water at 68 degrees Fahrenheit (20°C)
inHg°C
inches of mercury at 0 degrees Celsius
ftH2O°F
feet of water at 68 degrees Fahrenheit (20°C)
mmH2O°F
millimeter of water at 68 degrees Fahrenheit (20°C)
mmHg°C
millimeter of mercury at 0 degrees Celsius
psi
pounds per square inch
bar
bars
364Ax-Gx Instruction Manual
>
Display Eng.
Edit
and scroll with a up an d
Unit, and
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

364a series