Installation Instructions; Operating Conditions; Installation Options; Horizontal Installation - LinMot PR02-88 Series Installation Manual

Linear rotary motors
Table of Contents

Advertisement

Installation Guide Linear Rotary Motors

4 Installation instructions

4.1 Operating Conditions

Maximum ambient temperature limits: -10 °C...80 °C
Internal temperature sensor error occurs at: 90 °C
The max. installation altitude is 4'000 m above sea level.
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.

4.2 Installation Options

The PR02 linear motors have a centric fit (technical data in the chapter "Dimensions") on the front so that an
exact alignment of the rotary axis is possible.
The following sketches show examples of different installation options. The detailed mounting dimensions
can be found in the chapter "Dimensions".

4.2.1 Horizontal Installation

Ordering information
Item
Nut N8/M6

4.2.2 Vertical Installation

Page 10 / 34
The PR02 linear rotary motor can be mounted horizontally using the
T-slots at the bottom.
T-nuts M6 can be used for fastening.
Description
Nut for 8 mm T-slots with M6 thread
The T-slots on the underside of the PR02 are used for stable
vertical mounting (see explanation above). In addition, the front of
the motor should be fixed using the 4 tapped holes. The positions of
the tapped holes can be found in the "Dimensions" section.
PR02-88
ENG
Item-No.
0150-2558
NTI AG / LinMot