4 Installation Instructions

4.1 Operating Conditions

Maximum ambient temperature limits:
-10 °C...80 °C (non-condensing!)
Internal temperature sensor error occurs at:
90 °C
Max. Installation altitude
The maximum installation altitude is 4000 m above sea level.
From 1000 m onwards, a derating of 0.5% per 100 m must be taken into account for the
nominal force or nominal torque in the case of air cooling.

4.2 Installation Options

The PR01 linear rotary motors have a centric fit (see drawing in chapter « Dimensions ») on the front side, so
that an exact alignment of the rotation axis is possible.
Mounting only via the front screws is generally not sufficient (vibrations, transverse load) and must be
supplemented by an additional support. For vibration reasons, a support as far back as possible is
preferable. See the mounting examples in the following chapter. Please note that a tolerance compensation
(see next chapter) must be provided so that the motor is not installed in the machine under tension. The
detailed mounting dimensions can be found in chapter 10 "Dimensions". The corresponding CAD files are
available in the LinMot eCatalog
NTI AG / LinMot
https://shop.linmot.com/
PR01-52-SSCH