Panasonic MN34120PAJ Manual page 50

Area sensor
Table of Contents

Advertisement

Confidential
Until : Indefinite
Return sequence from Power save 3-2
Return sequence from power save 3-2 to normal is as follows.
(1) MCLK Input
Power save release waiting: 10T@MCLK
(2) PSV pin: "L" ⇒ "H"
(3) PLLREG register writing
PLL oscillation stability waiting.
(4) CKG reset register (0x0000[4]) writing: "L" ⇒ "H"
(5) Registers other than PLLREG register writing.
Up/Down converter circuit stability waiting.
(6) TG reset register (0x0000[8]) writing: "L" ⇒ "H"
- HD input beginning
- VD input timing waiting (wait over 5HD-input)
(7) VD/HD Input
External pin
PSV
MCLK
Don't care(High/Low)
SCK
SI
SCS
VD
HD
LVDS
Internal signal (Register)
Power save register
CKG-Reset register
TG-Reset register
Figure 1.6.3.3-6 Timing chart of return sequence from Power save 3-2 to normal
2015/10/01
Enactment
Revision
Specifications
(1)
(2)
(3)
Don't care(High/Low)
Don't care(High/Low)
4'b0001
10T@MCLK
Tpll
Generalplus Technology Inc.
MN34120PAJ
Total Page
96
(4)
(5)
(6)
(7)
4'b0011
HD input
Tvchp
Tpulvds
Panasonic Semiconductor Solutions Co., Ltd.
Page
48
Blanking

Advertisement

Table of Contents
loading

Table of Contents