Until : Indefinite
Shift sequence of Power save 3-1 and Power save3-2
Shift sequence from normal to power save 3-1 is as follows
(1) Power save register (0x000E[3:0]) writing: "4'b0011" ⇒ "4'b0001"
TG reset register (0x0000[8]) writing: "H" ⇒ "L"
CKG reset register (0x0000[4]) writing: "H" ⇒ "L"
Power save register (0x000E[3:0]) writing timing waiting: Hcycle
Shift sequence from normal to power save 3-2 is as follows
(1) TG reset register (0x0000[8]) writing: "H" ⇒ "L"
CKG reset register (0x0000[4]) writing: "H" ⇒ "L"
PSV-pin polarity change timing waiting: Hcycle
(2) PSV-pin: "H" ⇒ "L"
External pin
PSV
"High"
MCLK
SCK
SI
SCS
VD
HD
LVDS
Blanking
Internal signal (Register)
Power save register
CKG-Reset register
TG-Reset register
Figure 1.6.3.3-2 Timing chart of shift sequence from normal to Power save 3-1 and Power save 3-2
2015/10/01
Enactment
Revision
Specifications
(1)
(2)
Data output
Blanking
4'b0011
Hcycle or more
Don't care(High/Low)
Don't care(High/Low)
Don't care(High/Low)
Power save3-1:4'b0001 / Power save3-2:Don't care