MANUAL CHANGES - MODEL 3000
Wavetek's
product
improvement
program
incorporates
the
latest
electronic
developments
into
these
instruments
as
rapidly
as development
and
testing
permit .
Due
to
the
time
required to document
and print
these
instruction
manuals,
it
is not
always possible to
include
the changes
in
the original
printing. The following schematics and drawings have been changed .
DPS2A has replaced DPS2 ; M10W-9 has replaced M10W ; M29--2 has replaced M29-1 ;
M31A has replaced M31 ; M32A has replaced M32 ; M41A-1 has replaced M41A . In all
cases where
the
former assembly
is
mentioned
in
the manual
text,
the new
assembly
name
should
be
understood .
All
specifications,
adjustments,
and
procedures, have been updated in the manual text .
GENERAL
Two gaskets are being installed under the M9W and MlOW-9 modules to
further reduce RFI radiation . The hold-down screws for these modules
are
3/8"
instead
of
5/16"
as
for
the
other modules .
The
gasket
material consists of nickel fibers imbedded in a silicone elastomer .
Loose fibers may penetrate the skin or short out a chassis terminal ;
therefore use care when handling the gasket .
M35-1
R15 is now 1 .8 kohm, W-I PN 4700-15-1801 .
M41A-1
C17 is reversed on the schematic .
Rev A
M34
11/15/84
M34 Schematic should indicate C13* .
Rev B
M9W to M9W-7
11/14/85
The M9W-7
Sweep Oscillator module replaces
the M9W module
in the
Model
3000
Signal
Generators .
The
M9W-7
module
uses
a
control
circuit to automatically set the phased-locked loop voltage in PLL3
to zero . This eliminates the Pot "D" adjustment in the M9W module .
Disregard the first paragraph of Section 5 .3 .7 in the manual, since
there is no pot "D" . The M9W-7 parts list and schematic replace the
M9W documents may be found at the end of the Manual Changes .
Rev C
5 .3 .6 PHASE-LOCKED LOOP 2 ADJUSTMENT M32A
1/7/86
Revise the first paragraph beginning with line 3 to read :
Connect
a digital voltmeter
to M32A PIN 14 .
The DVM should read
between +0 .5 and +2 .5
VDC .
If
the leveler voltage is within this
range, DO NOT adjust the M30-4t trimmer capacitors .
(The dash number
# depends upon the instrument model number .)
If the leveler voltage is not between +0 .5 and +2 .5 VDC, carefully
adjust trimmers A and B on top of the M30-# until the voltage is
correct .