OPERATION
O2
Accuracy Lamps
Indicate frequency accuracy .
±0 .001% in CW
and AM modes, ±(0 .001% + 10 kHz) in FMxl and
±(0 .001% + 45 kHz) in FMx100 .
Typically the
lamp will flash for a few seconds after power
is turned on .
Under
normal
operation a
steady
light indicates that
the unit
is
phase-locked and the frequency accuracy in-
dication is valid .
A continuously flashing
light indicates that one or more of the phase
lock loops is open .
(The open loop can be
identified
by removing the
top cover
and
looking for the corresponding "module fault"
light .)
O3
Output Level Meter
Indicates output level
over a
10 dB range
in VRMS and dBm.
4O
Unlevel Lamp
Indicates that the output level accuracy
is
not valid when the lamp is on .
O5
Attenuator
Controls the output level over a140 dB range
from +10
to -130 dBm .
The Attenuator dial
is calibrated in dB and VRMS .
6O
Vernier
Controls
the
output
level
over an 11 dB
range .
O7
AM/FM Vernier
Is calibrated from O to 5 kHz FM peak devia
tion and from 0 to 90% AM. This control per-
mits
precise
AM and FM settings
with the
mode switch in AM and FMxlor FMx100 respec-
tively and the frequency
switch in 400 Hz,
1 kHz or Ext .
The vernier also serves as a
manual amplitude and frequency control with
the frequency switch in vernier . The vernier
provides
up to +6 dB amplitude change when
the mode switch is in
the AM and also pro-
vides up to a +5 kHz or up to +500 kHz fre-
quency change
when the
mode switch
is in
FMxl and FMx100 respectively .
Frequency Switch
Selects
vernier, for
manual
amplitude or
frequencyicontrol, 400 Hz and 1 kHz internal
modulation and external modulation .
O9
Ext
Modulation input accepts a DC to 20 kHz sig-
nal for AM and a DC to 25 kHz for FM .
A 10
V peak-to-peak signal into
a 600 ohm impe
dance calibrates the AM/FM vernier full scale .
A lesser. input voltage will result in a pro-
portional full scale calibration of the AM/
FM vernier .
Therefore, a 1 volt
peak-to-
peak signal into 600 ohms
will result in a
2-3