4 .18
RFI TEST
2 .
Use the setup in Figure 4-8 .
Connect the sweep/signal
generator to the
input port, the spectrum
analyzer to the
reflected output port and
the coaxial short to the device-
under-test port of the VSWR bridge .
3 .
Set the sweep/signal generator output level to -10 dBm,
the mode to CW and the center frequency to 250 MHz .
4 .
Set the
spectrum analyzer to span 0 to 500 MHz and the
bandwidth to 300 kHz .
Use the log reference level controls
to calibrate the 250 MHz signal at the top line (0 dB refer-
ence) of the display graticule .
5 .
Disconnect the
coaxial short
and connect the
device-
under-test port of
the VSWR bridge to the Signal Generator
RF out connector .
Use the
sweep/signal generator
center
frequency control to tune from 1 to 520 MHz and verify that
the signal level
in the display is >21
dB below the 0
dB
reference .
Disregard the signal
at 520 MHz .
Record
the
reading in
dB below the
reference on line 45
of the PTR .
Model 3000
Sweep/Signal Generator
Signal Generator
Figure 4-8 .
Test Setup
PERFORMANCE TESTS
Step 2
Coaxial
SMrt
SPECIFICATION
<1 .0 pV is
induced in a
two-turn, one-inch
diameter loop
which is held one inch away from any surface .
Loop feeds a
50 ohm receiver .