Wavetek 3000 Instruction Manual page 204

Signal generator
Table of Contents

Advertisement

OPTION - 3
Install the M35-1 module in the location
Before use, the module should be tested
by the
procedure
shown
in
Operation
Check .
Note :
The above information applies to
all 3000 Series instruments except Models
3002
and 3004 .
For these instruments
the M35-1 is
replaced by 1435-2,
which
permits operation from .001 to 520 MHz,
but does not inlcude DC blocking .
All
other specifications, operating instruc-
tions, and descriptions apply.
QTY
OPTION
3 FIELD INSTALLATION KIT
DESCRIPTION
PART #
1
RF Circuit Breaker Module
M35-1
1
RF Cable
W1A
1
RF Cable
WIB
1
6/32 x 5/8 Screw
HS101-610
shown in
Figure 8/3-2 and
secure with
the 6-32 hold-down
screw .
Remove the
front-panel
RF
output cable, W1,
and
replace with WlA
and W1 .B
which
will
route
the
RF
output signal thru the
?435-1 module .