Output Protection
FREQUENCY RANGE
INSERTION LOSS
TRIP TIME
RF TRIP VOLTAGE
MAX RF
DC BLOCKING VOLTAGE
RF Level Programing
POWER LEVEL
PROGRAMMED RANGE
ACCURACY EACH STEP
S14ITCHING SPEED
IMPEDANCE
FLATNESS
TABLE 8/1B-1 . SPECIFICATIONS
1 to 520 MHz ( .001 to 520 MHz on 3002B)
<0.2 dB
<2 msec
4 .5 to 5 .5 volts (0 .5 W)
50 W
100 volts max (N/A on 3002)
The maximum calibrated output is +12 dBm
( .891 VRMS) when Option 1B is installed
0 to 90 dB in 10 dB steps ; 0 dB reference
point
is set to
desired
value by the
instrument
front-panel
Attenuators .
E .g ., if 0 dB reference is set to O dBm,
then
range is 0 dBm
to -90 dBm .
if 0
dB
reference
is set to
-5Q dBm, then
range is -50 dBm to -140 dBm.
10 dB +0 .1 dB
10 dB step :
Typ . < 3 msec
Max . < 6 msec
50 ohm (SWR < 1 .3)
+0 .75 dB
OPTION 1B
Need help?