ETAS
Sensor Supply
Number of channels
Arrangement of channels
Assignment of channels
Output voltage
Output current
Output resistance
Accuracy of output voltage
Ripple of output voltage V
Max. voltage drift (temperature)
Run up time of output voltage
Electrical connection
Maximum voltage
Protection
Diagnostics
ES930.1 - User Guide
4
2 channels at "AI 1-4" connection and
2 channels at "AI 5-8" connection
Assignment to sensors or input chan-
nels of the ES930.1 can be randomly
configured
Configurable per channel:
predefined values ("Off", +5 V, +8 V,
+10 V, +12 V, +15 V) or
user-defined (+5 V to +15 V, resolution
10 mV)
Max. 50 mA per channel (at 5 V output
voltage)
Max. 30 mA per channel (at 15 V out-
put voltage, all channels loaded simul-
taneously)
<0.5 (measured at connector)
±(5 mV + V
load)
<30 mV (20 MHz bandwidth)
pp
±2 mV/K
32 ms (all channels simultaneously)
Sensor supply voltage ground con-
nected with supply voltage ground of
module
0 V (short circuit) to +26 V DC
Outputs CH(n) and ground
CH(n)_GND protected each with a
fuse against fault-current
Short-circuit detection per channel; if
permissible total output is exceeded,
all channels are switched off
Technical Data
* 0.2%) (with 500
sensor
97