13.9

Electrical Data

NOTE
Unless described otherwise, the electrical data of the ES930.1 were mea-
sured directly at the contacts of the module.
13.9.1
Power Supply
Operating voltage
Power consumption
Power consumption
Power consumption
Overvoltage category
(AC mains supply)
1)
: without sensor supply
2)
: with sensor supply, 30 mA load at 15 V
13.9.2
Host ("IN" Connection)
Connection
Protocol
IP address
NOTE
For the successful initialization of the network card of your PC, observe chap-
ter 13.8.2 on page 90.
ES930.1 - User Guide
Operating voltage for the module at
"IN" connection:
7 V to 29 V DC
Separate operating voltage for the
Half-bridges at "PS" connection:
7 V to 32 V DC
1)
Typ. 4.5 W at 12 V
2)
Typ. 7.8 W at 12 V
Max. 15 W
II
100Base-T Ethernet; 100 Mbit/s,
full duplex
XCP on UDP/IP
Dynamic via INCA or
ES93x Configuration Tool
(default setting 192.168.40.44)