ETAS ES930.1 User Manual page 63

Multi-i/o module
Table of Contents

Advertisement

ETAS
10.4
Control of the Channel Group and its Half-bridges
The Half-bridges are controlled with the "Control PS n" signals. The two Half-
bridges of the channel group are jointly enabled or disabled with the "Enable PS
n/n+1" signal..
10.4.1
Control PS
The "Control PS n" signal of a digital output channel is used to control a Half-
bridge (see chapter 9.1.7 on page 54). The output signal of each one of the dig-
ital output channels is firmly assigned to a Half-bridge (power stage). This
assignment cannot be changed:
Digital Output Channel
DO 1
DO 2
DO 3
DO 4
DO 5
DO 6
10.4.2
Enable PS
The "Enable PS n/n+1" signal allows releasing or blocking one channel group
each, i.e. the two corresponding Half-bridges. The release or blocking of a sin-
gle Half-bridge (power stage) is not possible. These control signals are
assigned to the Half-bridges, i.e. one channel group each, as pairs:
a common power stage enable signal for the Half-bridges 1 and 2
a common power stage enable signal for the Half-bridges 3 and 4
a common power stage enable signal for the Half-bridges 5 and 6
Start and default values of these control signals can be defined in the configu-
ration software.
NOTE
For rapid prototyping applications, the release or blocking of the two Half-
bridges of a channel group with the "Enable PS n/n+1" signals enables a safe
starting and shutting down of the system during the Init and Exit tasks by the
RP model according to the user definition.
ES930.1 - User Guide
Half-bridges ("PS" Connection)
Assigned Half-bridge (Power Stage)
PS 1
PS 2
PS 3
PS 4
PS 5
PS 6