ETAS
7
Outputs to the Sensor Power Supply
The ES930.1 is equipped with four outputs for the power supply of sensors that
are available at the connections "AI 1-4" and "AI 5-8".
7.1
Channel Groups
The two sensor supply voltage channels at the "AI 1-4" connection and the two
sensor supply voltage channels at the "AI 5-8" connection are combined into
channel groups.
•
Channel group at "AI 1-4" connection:
Sensor power supplies, channel 1 and channel 2
•
Channel group at "AI 5-8" connection:
Sensor power supplies, channel 3 and channel 4
7.2
Assemblies of the Sensor Supply Channels
7.2.1
Overview
Sensor Supply Channel n
Overcurrent
Overcurrent
Protection
Protection
Fig. 7-1
The four sensor supply voltage channels of the ES930.1 feature an identical
design and provide four individual, separately configurable sensor supply volt-
ages. Each channel consists of the following assemblies (see block diagram in
Fig. 7-1 on page 49):
•
D/A converter
•
Overcurrent protection
•
Overload detection
The functionality of all sensor supply voltage channels can be configured sep-
arately. An additional external power supply device for the sensor supply volt-
age is not required. In each channel, the sensor supply voltage is generated
from the module operating voltage.
7.2.2
D/A Converter
The 14-bit D/A converter of the channel transforms the digital input signal pro-
vided by the output unit into a changeable sensor supply voltage. The user can
switch off the sensor supply voltage of each sensor channel in the application
program, select one of the predefined values between +5 V and +15 V or enter
or specify any value within the range of values.
ES930.1 - User Guide
Overload
Detection
Sensor Supply Voltage Channel
Outputs to the Sensor Power Supply
14 Bit D/A
Output Unit
Converter
Diagnosis
Unit
49