ETAS
5
Digital Input Channels ("DI" Connection)
The ES930.1 provides four digital input channels at the "DI" connection for dif-
ferent measuring functions (status, counter, timer).
5.1
Assemblies of the Digital Input Channels
5.1.1
Overview
Digital Input Channel n
Fig. 5-1
The digital input channels "DI 1" to "DI 4" of the ES930.1 feature an identical
design and consist of an input stage with signal acquisition and signal process-
ing. The input stage of each channel (see in Fig. 5-1 on page 31) consists of the
following assemblies :
•
Schmitt trigger (TTL-compatible)
•
Glitch filter
•
Capture unit
•
Counter unit
•
Timeout detection
•
Event raster source
•
Counter overflow detection
The digital input channels are dimensioned for TTL-compatible input voltages.
The minimum pulse width is restricted to 120 ns. This restriction avoids acquir-
ing interference pulses at the measuring channels.
The functionality of all digital input channels can be configured separately.
ES930.1 - User Guide
Glitch Filter
Digital Input Channels
Digital Input Channels ("DI" Connection)
Counter Unit
Capture Unit
Counter
Overflow
Detection
Timeout
Detection
Event Raster
Source
Measure-
ment
Unit
Diagnosis
Unit
Event Unit
31