Problem
The measurements do
not start.
ES930.1 - User Guide
Diagnostics questions
Are you being asked to
update in the INCA moni-
tor log or in the Config
tool?
Does the module not fur-
nish any data?
You are using the ETAS
daisy chain configura-
tion tool and the module
does not furnish any
data?
Does the module not fur-
nish any usable data?
Handling of Problems
Possible solutions
Update the modules.
Check whether your
power supply and your
measuring setup meets
the requirements
according to chapter 3.5
on page 21.
Check whether the
cabling of the hardware
to the PC is correct and
functional.
Check whether the mod-
ules in the module chain
are correctly connected.
Check whether you
changed the position of
one or several modules
in the chain.
Check whether you
loaded the measuring
configuration into the
module chain.
Check whether you
assigned the same IP
address to two module
chains.
Check whether the sen-
sor or the sensor supply
is correctly connected.