Problems with the ES930.1

The following table lists some possible problems together with a possible solu-
tion. In case of additional questions, please contact our technical service (see
chapter 16 on page 133).
Problem
The ES930.1 cannot be
found by the application
software.
The application software
does not find any ETAS
daisy chain modules.
ES930.1 - User Guide
Diagnostics questions
Is the network card cor-
rectly configured?
Is the hardware con-
nected to the PC?
Is the ER LED of the
ES930.1 flashing red and
are the LEDs of the ETAS
daisy chain modules
flashing green?
Is the network card cor-
rectly configured?
Did you install the
required firmware on the
module?
Did you install the
required application soft-
ware?
Power supply
Is the hardware con-
nected to the PC or the I/
O port of the ES910?
Are the modules in the
module chain correctly
connected?
Handling of Problems
Possible solutions
Check whether your net-
work card is configured
according to chapter
13.8.2 on page 90.
Check whether the con-
nection is correct
Check whether the func-
tion for automatically
switching to the power-
save mode is enabled on
1)
your PC card
. Disable
this function.
INCA, Config Tool and
HSP mode:
Check whether your net-
work card is configured
according to chapter
13.8.2 on page 90.
Check with HSP whether
the required firmware is
installed on the module.
Check whether the appli-
cation software installed
on your PC meets the
requirements in chapter
13.8.3 on page 91.
Check whether your
power supply and your
measuring setup meets
the requirements
according to chapter 3.5
on page 21.
Check whether the
cabling is correct.
Check whether the
cabling is correct.