Cn (Exit Command Mode); Gt (Guard Times); Firmware Commands; Vl (Version Long) - Digi XBee SX 868 User Manual

Radio frequency (rf) module
Hide thumbs Also See for XBee SX 868:
Table of Contents

Advertisement

AT commands
Default
0x64 (10 seconds)

CN (Exit Command Mode)

This command applies to the XBee SX 868 RF Module.
Immediately exits Command Mode and applies pending changes.
Parameter range
N/A
Default
N/A

GT (Guard Times)

This command applies to the XBee SX 868 RF Module.
Set the required period of silence before and after the command sequence characters of the
Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering
Command mode.
Parameter range
0x2 - 0x95C (x 1 ms)
Default
0x3E8 (one second)

Firmware commands

The following AT commands are firmware commands.

VL (Version Long)

This command applies to the XBee SX 868 RF Module.
Shows detailed version information including the application build date and time.
Parameter range
[read-only]
Default
N/A

VR (Firmware Version)

This command applies to the XBee SX 868 RF Module.
Reads the firmware version on a device.
Parameter range
0 - 0xFFFFFFFF [read-only]
XBee® SX 868 RF Module User Guide
Firmware commands
157

Advertisement

Table of Contents
loading