AT commands
Set or read the Associate LED blink time. If you use the D5 command to enable the Associate LED
functionality (DIO5/Associate pin), this value determines the on and off blink times for the LED when
the device has joined the network.
If LT = 0, the device uses the default blink rate: 500 ms for a sleep coordinator, 250 ms for all other
nodes.
Parameter range
0x14 - 0xFF (x 10 ms)
Default
0

RP (RSSI PWM Timer)

This command applies to the XBee SX 868 RF Module.
The PWM timer expiration in 0.1 seconds. RP sets the duration of pulse width modulation (PWM)
signal output on the RSSI pin.
When RP = 0xFF, the output is always on.
Parameter range
0 - 0xFF (x 100 ms)
Default
0x28 (four seconds)

I/O sampling commands

The following AT commands configure I/O sampling parameters.

AV (Analog Voltage Reference)

This command applies to the XBee SX 868 RF Module.
The analog voltage reference used for A/D sampling.
Parameter range
0, 1
Parameter
0
1
Default
1

IC (DIO Change Detection)

This command applies to the XBee SX 868 RF Module.
Set or read the digital I/O pins to monitor for changes in the I/O state.
XBee® SX 868 RF Module User Guide
Description
1.25 V reference
2.5 V reference
I/O sampling commands