7
Commissioning
7.2
Initial commissioning
Inbetrieb_Erstinbetrieb_Zusatz
7-4
1
SS1 Activate
0
1
SS1 SIL3/Reset
0
1
STO Acknowledge
0
1
Ready
0
1
LED "CONFIG"
0
1
LED "RUN"
0
SS1 Activate: Input for safety function SS1
SS1 SIL3/Reset: Input for SIL3 and reset
STO Acknowledge: Output for feedback from safety function STO
Ready: Output for operating status of the safety card
"CONFIG" LED: Configuration data is downloaded
"RUN" LED: System is ready
RUN: System is ready for operation
CONFIG: Downloading the configuration data
STARTUP: System starts up with the downloaded configuration
The inputs and outputs on the safety card can be tested using
The dynamic program display in the safety card's Configurator
PDrive and PScope from PMCmotion control tools