10. Advanced functions
10.8

Auto tuning

Group
LED Display
Function
H41
group 2
H42
H44
Automatic measuring of the motor parameters is provided.
The measured motor parameters in H41 can be used in Auto Torque Boost and Sensorless Vector Control.
☞ Caution :
Auto tuning should be executed after stopping the motor. Motor shaft must not run by the load during H41 – [Auto
tuning].
H41 : When H41 is set to 1 and press the Prog/Ent (•) key, Auto tuning is activated and "TUn" will
appear on the LED keypad. When finished, "H41" will be displayed.
H42, H44 : The values of motor stator resistance and leakage inductance detected in H41 are
displayed, respectively. When H93 – [Parameter initialize] is done, the preset value corresponding to
motor type (H30) will be displayed.
Press the STOP/RST key on the keypad or turn on the BX terminal to stop the Auto Tuning.
If Auto tuning of H42 and H44 is interrupted, the preset value will be used.
See page 10-12 for motor preset parameter values.
☞ Caution :
Do not enter any incorrect value as stator resistance and leakage inductance. Otherwise, the function of Sensorless
vector control and Auto torque boost could be deteriorated.
Parameter Name
[Auto tuning]
[Stator resistance (Rs)]
[Leakage inductance (Lσ)]
10-10
Set
Min/Max
value
Range
0/1
1
-
0/14.0
-
0/300.00
Factory
Unit
Defaults
-
0
-
-
mH