LG SV-iC5 Series Instruction Manual page 55

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

LED
Parameter
display
Name
H51
[P gain for PID
controller]
H52
[Integral time
for PID
controller
(I gain)]
H53
Differential
time for PID
controller
(D gain)
H54
F gain for PID
controller
H55
[PID output
frequency
limit]
H70
[Frequency
Reference for
Accel/Decel]
H71
[Accel/Decel
time scale]
H72
[Power on
display]
Min/Max
Range
0/999.9
This parameter sets the gains for the PID
[%]
controller.
0.1/32.0
[sec]
0.0 /30.0
[sec]
0/999.9
This is the Feed forward gain for the PID
[%]
controller.
0/400
This parameter limits the amount of the
[Hz]
output frequency thru the PID control.
The value is settable within the range of
F21 – [Max frequency] and H23 – [Start
frequency].
0/1
0
The Accel/Decel time is the time that
takes to reach the F21 – [Max
frequency] from 0 Hz.
1
The Accel/Decel time is the time that
takes to reach a target frequency from
the run frequency.
0/2
0
Settable unit: 0.01 second.
1
Settable unit: 0.1 second.
2
Settable unit: 1 second.
0/13
This parameter selects the parameter to be
displayed on the keypad when the input
power is first applied.
0
Frequency command
1
Accel time
2
Decel time
3
Drive mode
4
Frequency mode
Description
7-13
7. Function list
Function group 2
Factory
Adjustable
defaults
during run
300.0
O
1.0
O
0.0
O
0.0
O
60.0
O
0
X
1
O
0
O
SV-iC5
Page
10-8
10-8
10-8
10-8
10-8
9-10
9-11
11-2