LG SV-iC5 Series Instruction Manual page 63

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

LED
Parameter
display
name
I60
[Inverter
station
number]
I61
[Baud rate]
I62
[Drive
mode
select
after
loss
of
frequency
command]
I63
[Wait
time
after loss of
frequency
command]
Min/Max
range
2
-
3
-
4
5
6
7
1/32
This parameter is set when the inverter
uses RS485 communication.
0/4
Select the Baud rate of the RS485
0
1
2
3
4
0/2
It is used when frequency command is
given via V1 and I terminal or communication
option.
0
1
2
0.1/12
This is the time inverter determines
[sec]
whether there is the input frequency command
or not. If there is no frequency command input
during this time, inverter starts operation via
the mode selected at I62.
Description
-
-
-
-
-
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
Continuous operation
Free Run stop (Coast to stop)
Decel to stop
7-21
7. Function list
I/O group
Factory
Adjustable
defaults
during run
1
O
3
O
0
O
1.0
-
SV-iC5
Page
12-7