LG SV-iC5 Series Instruction Manual page 45

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

LED
Parameter
display
name
F 0
[Jump code]
F 1
[Forward/
Reverse run
disable]
F 2
[Accel pattern]
F 3
[Decel pattern]
F 4
[Stop mode
select]
F 8
[DC Brake
1)
start
frequency]
F 9
[DC Brake
wait time]
F10
[DC Brake
voltage]
F11
[DC Brake
time]
F12
[DC Brake
start voltage]
F13
[DC Brake
start time]
F14
[Time for
magnetizing a
motor]
1) : Set F4 to 1 (Stop via DC brake ) to view this function
Min/Max
range
0/60
This parameter sets the parameter code
number to jump.
0/2
0
Fwd and rev run enable
1
Forward run disable
2
Reverse run disable
0/1
0
Linear
1
S-curve
0/2
0
Decelerate to stop
1
Stop via DC brake
2
Free run to stop
0/60 [Hz]
This parameter sets DC brake start
frequency.
It cannot be set below F23 - [Start
frequency].
0/60 [sec]
When DC brake frequency is reached, the
inverter holds the output for the setting time
before starting DC brake.
0/200
This parameter sets the amount of DC
[%]
voltage applied to a motor.
It is set in percent of H33 – [Motor rated
current].
0/60 [sec]
This parameter sets the time taken to
apply DC current to a motor while motor is at
a stop.
0/200
This parameter sets the amount of DC
[%]
voltage before a motor starts to run.
It is set in percent of H33 – [Motor rated
current].
0/60 [sec]
DC voltage is applied to the motor for DC
Brake start time before motor accelerates.
0/60 [sec]
This parameter applies the current to a
motor for the set time before motor
accelerates during Sensorless vector control.
Description
7-3
7. Function list
Function group 1
Factory
Adjustable
defaults
during run
1
O
0
X
0
X
0
X
5.0
X
0.1
X
50
X
1.0
X
50
X
0
X
1.0
X
SV-iC5
Page
5-5
9-8
9-13
9-18
10-1
10-1
10-1
10-1
10-2
10-2
10-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents