9. Basic functions
Run command setting 2 at FX and RX terminals
Group
LED Display
Drive
drv
group
I/O group
I20
I21
Set the drv to 2.
Set I20 and I21 to 0 and 1 to use P1 and P2 as FX and RX terminals.
FX: Run command setting. Motor runs in forward direction when RX terminal (P2) is OFF.
RX: Direction of motor rotation select. Motor runs in reverse direction when RX terminal (P2) is ON.
FX/RX Run Disable
Group
LED Display
Drive
drC
group
Function
F 1
group 1
Select the direction of motor rotation.
0 : Forward and Reverse run enable
1 : Forward run disable
2 : Reverse run disable
Parameter Name
[Drive mode]
(Run/Stop mode)
[Multi-function input terminal
P1 define]
[Multi-function input terminal
P2 define]
Frequency
FX
RX
Parameter Name
[Direction of motor rotation
select]
[Forward/Reverse
disable]
Set
Min/Max
Value
Range
2
0
1
Set
Min/Max
Value
Range
-
run
-
9-8
Factory
Defaults
0/3
1
0/24
0
0/24
1
Factory
Defaults
F/r
F
0/2
0
SV-iC5