LG SV-iC5 Series Instruction Manual page 110

Lg inverter instructions manual
Hide thumbs Also See for SV-iC5 Series:
Table of Contents

Advertisement

11. Monitoring
User display select
Group
LED Display
Drive group
Function
group 2
The selected item in H73- [Monitoring item select] can be monitored in vOL- [User display select].
H73 : Select one of the desired item numbers.
Enter motor efficiency indicated on motor nameplate to H36 to display correct torque
Power on display
Group
display
Function
group 2
Select the parameter to be displayed on the keypad when the input power is first applied.
Parameter Name
[User display select]
vOL
H73
[Monitoring item select]
H73
[Monitoring item
select]
LED
Parameter Name
[Power on display]
H72
`
Set
value
-
-
0
Output voltage [V]
1
Output power [kW]
2
Torque
0
Frequency command (0.0)
1
Accel time (ACC)
2
Decel time (DEC)
3
Drive mode (drv)
Frequency mode (Frq)
4
5
Multi-step frequency 1
6
Multi-step frequency 2
7
Multi-step frequency 3
8
Output current (CUr)
9
Motor rpm (rPM)
10
Inverter DC link voltage (dCL)
11
User display select (vOL)
Fault display 1
12
Fault display 2
13
11-2
Min/Max
Factory
range
default
0/2
0
Setting
SV-iC5
Unit
Factory
default
0