14.

Specifications

14.1

Technical data

Input & output ratings
Model : SV xxx iC5 – 2x
1
Max motor capacity
Capacity [kVA]
Output
FLA [A]
ratings
Frequency
Voltage
Voltage
Input
Frequency
ratings
Current
Control
Control mode
Frequency setting resolution
Accuracy of Frequency command
V/F Ratio
Overload capacity
Torque boost
Operation
Operation mode
Frequency setting
Operation features
Input
Multi-function terminal
Multi-function
Output
collector terminal
1
Indicates the maximum applicable motor capacity when using a 4-pole LG Standard motor.
2
Rated capacity is based on 220V.
3
Max settable freq is 300Hz when H30 is set to 3 "Sensorless Vector Control".
4
Max output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be
programmed.
004
[HP]
0.5
[kW]
0.4
2
0.95
2.5
3
0 ~ 400 [Hz]
Three Phase 200 ~ 230V
Single Phase 200 ~ 230V (±10%)
50 ~ 60 [Hz] (±5%)
5.5
V/F control, Sensorless vector control
Digital: 0.01Hz
Analog: 0.06Hz (Max. frequency : 60Hz)
Digital: 0.01% of Max. output frequency
Analog: 0.1% of Max. output frequency
Linear, Squared Pattern, User V/F
Software: 150% for 60 s
Auto/Manual torque boost
Keypad/ Terminal/ Communication option selectable
Analog: 0 ~ 10[V], 0 ~ 20[mA], Keypad Potentiometer
Digital : Keypad
PID control, Up-Down operation, 3-wire operation
NPN/ PNP selectable
Function: (refer to page 3-5)
open
Operating status
008
1
0.75
1.9
5
4
9.2
14-1
14. Specifications
015
2
1.5
3.0
8
16
Function: (Refer to page 11-6)
SV-iC5
022
3
2.2
4.5
12
21.6