14. Specifications
Multi-function
terminal
Analog output
Protective functions
Over-voltage, Under-voltage, Over-current, Ground fault current detection, Over-temperature of inverter
Inverter Trip
and motor, Output phase open, Overload, Communication error, Loss of frequency command, H/W fault
Alarm
Stall prevention, Overload
Conditions
Momentary
Less than 15 msec : Continuous operation
power loss
More than 15 msec : Auto Restart enable
Environment
Cooling
Forced air cooling
method
Degree
of
Open, Pollution degree 2
protection
Ambient
-10°C ~ +50°C
temperature
Storage
-20°C ~ +65°C
temperature
Relative
Less than 90% (no condensation)
humidity
Altitude,
1,000m above sea level, Max. 5.9m/sec
Vibration
Application
Protected from corrosive gas, combustible gas, oil mist or dust
site
relay
Fault output (N.O., N.C.)
0 ~ 10 Vdc : Frequency, Current, Voltage, DC link voltage selectable
2
(0.6G)
14-2
SV-iC5