Safety Data - ABB ACS880-37LC-0390A-7 Hardware Manual

Industrial drives
Table of Contents

Advertisement

Safety data

The safety data for the Safe torque off function is given below.
Note: The safety data is calculated for redundant use, and does not apply if both STO
channels are not used.
SFF
Frame
SIL
PL
size
(%)
R8i
3
e
>99
2×R8i
3
e
>99
3×R8i
3
e
>99
4×R8i
3
e
>99
5×R8i
3
e
>99
6×R8i
3
e
>99
7×R8i
3
e
>99
8×R8i
3
e
>99
PFH
PFD
avg
(T
= 20 a)
1
(T
= 2 a)
1
(1/h)
5.0E-11
4.5E-07
6.2E-11
5.5E-07
7.3E-11
6.5E-07
8.4E-11
7.6E-07
9.5E-11
8.6E-07
1.1E-10
9.6E-07
1.2E-10
1.1E-06
1.3E-10
1.2E-06
The Safe torque off function 231
PFD
MTTF
DC
avg
D
(T
= 5 a)
(a)
(%)
1
1.1E-06
23970
≥90
1.3E-06
16330
≥90
1.6E-06
12390
≥90
1.9E-06
9980
≥90
2.1E-06
8360
≥90
2.4E-06
7190
≥90
2.6E-06
6310
≥90
2.8E-06
5620
≥90
T
M
Cat.
SC
HFT
CCF
(a)
3
3
1
80
20
3
3
1
80
20
3
3
1
80
20
3
3
1
80
20
3
3
1
80
20
3
3
1
80
20
3
3
1
80
20
3
3
1
80
20
3AXD10000078136 G

Advertisement

Table of Contents
loading

Table of Contents