Tüv Certificate - ABB ACS880-37LC-0390A-7 Hardware Manual

Industrial drives
Table of Contents

Advertisement

Term or abbre-
Reference
viation
PFH
IEC/EN 62061
diag
PL
EN ISO 13849-1
Proof test
IEC 61508, IEC 62061
SC
IEC 61508
SFF
IEC 61508
SIL
IEC 61508
STO
IEC/EN 61800-5-2
T
IEC 61508-6
1
T
EN ISO 13849-1
M
λ
IEC 61508-6
Diag_d
λ
IEC 61508-6
Diag_s
TÜV certificate
The TÜV certificate is available on the Internet at www.abb.com/drives/documents.
Description
Average frequency of dangerous failures per hour for the diagnostic
function of STO
Performance level. Levels a...e correspond to SIL
Periodic test performed to detect failures in a safety-related system
so that, if necessary, a repair can restore the system to an "as new"
condition or as close as practical to this condition
Systematic capability
Safe failure fraction (%)
Safety integrity level (1...3)
Safe torque off
Proof test interval. T
is a parameter used to define the probabilistic
1
failure rate (PFH or PFD) for the safety function or subsystem. Per-
forming a proof test at a maximum interval of T
the SIL capability valid. The same interval must be followed to keep
the PL capability (EN ISO 13849) valid.
See also section Maintenance.
Mission time: the period of time covering the intended use of the safety
function/device. After the mission time elapses, the safety device must
be replaced. Note that any T
guarantee or warranty.
Dangerous failure rate (per hour) of the diagnostics function of STO
Safe failure rate (per hour) of the diagnostics function of STO
The Safe torque off function 233
is required to keep
1
values given cannot be regarded as a
M