Replacing The Fan In The Incoming Cubicle - ABB ACS880-37LC-0390A-7 Hardware Manual

Industrial drives
Table of Contents

Advertisement

150 Maintenance

Replacing the fan in the incoming cubicle

WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death,
or damage to the equipment can occur. If you are not a qualified electrical
professional, do not do installation, commissioning or maintenance work.
WARNING!
Use the required personal protective equipment. Wear protective gloves and long
sleeves. Some parts have sharp edges.
1.
Stop the drive and do the steps in section
you start the work.
2.
Remove the shrouding in front of the fan (if any).
3.
Disconnect the fan wiring. Remove the CIO module.
4.
Remove the two screws and slide the fan unit out.
5.
Remove the four screws to detach the fan from the fan unit.
6.
Remove the eight screws surrounding the fan unit.
7.
Install a new fan in reverse order.
Electrical safety precautions (page 19)