Type designation label

The type designation label includes ratings, appropriate markings, a type designation and
a serial number, which allow the identification of each unit. A sample label is shown below.
Quote the complete type designation and serial number when contacting technical support.
...•
,,
n1111
MADE IN FINLAND
��o��lia 13
00380 Hetslnkl
Finland
FRAME:
3xR8I
+3xR8I
Liquid cooling
lcw 65 kA
IP54
UUCSA: max. 600 VAC
1
Type designation (see section
2
Frame size
Short-time withstand current rating (see chapter
3
UL/CSA specifications
4
Ratings. See also chapter
5
Valid markings
Serial number. The first digit of the serial number refers to the manufacturing plant. The next four digits
6
refer to the unit's manufacturing year and week, respectively. The remaining digits complete the serial
number so that there are no two units with the same number.

Type designation key

The type designation contains information on the specifications and configuration of the
drive. The first digits from left express the basic drive type. The optional selections are given
thereafter, separated by plus signs, eg, +E202. Codes preceded by a zero (eg. +0J400)
indicate the absence of the specified feature. The main selections are described below. Not
all selections are available for all types. For more information, refer to the ordering instructions
available separately on request.
Code
Description
Basic code
ACS880
Product series
Default configuration: liquid-cooled cabinet-installed drive, IP42 (UL Type 1), main switch-discon-
nector (and contactor) or breaker, aR fuses, ACS-AP-W assistant control panel (with Bluetooth),
ACS880-
EMC filter (category 3, 2nd Environment), du/dt filters, common mode filtering, standard wire
37LC
markings, ACS880 primary control program, Safe torque off function, coated circuit boards, bottom
entry and exit of cables with lead-through-type entries, USB memory stick containing circuit diagrams,
dimension drawings and manuals.
Size
xxxxx
Refer to the rating tables
Voltage range
525...690 V AC. This is indicated in the type designation label as typical input voltage levels
7
(3~ 525/600/690 V AC)
AC$880-37LC-2390A-7+3G335+AO 12+B055+C121
+C132+C138+C141 +C143+C149+C211+C240+D150
1
+E205+E210+F271+G300+G307+G313+G315+G316
+G320+G330+G334+G341 +G434+H351 +H353+H359
Input
U1 3- 525/600/690 VAC
11
2220 A
11
50/60 Hz
Output
U2 3- 0 ... U1
12
2390 A
2
12
0 ... 500 Hz
Sn 2856 kVA
3
Type designation
Technical data (page
Operation principle and hardware description 45
4
6
key)
Technical data (page
175).
5
II I II I I I I H I I I IIII I I I II I
S/N: 1183800453
175)); degree of protection;