11.6.11. Replacing the non-redundant fan

CAUTION
Heavy object. The fan weighs approximately 100 kg.

Fig. 76. Fan location, dimensions and weight

1
2
3
Key:
(1)
¼"
(2)
~70 mm
(3)
10 mm and 13 mm
(4)
Trolley
(5)
Lift truck

Fig. 77. Fan - tools and devices

1. Disconnect all power supplies to the drive and ground the drive according to Section 11.6.2,
"De-energizing the drive locally", page 145.
2. Switch off the motor starter of the fan.
The fan is now isolated from the auxiliary power supply.
3. Measure to confirm the absence of voltage.
4. Unplug the power supply cable (1, Fig. 78) of the fan.
5. Remove the bolts (2, Fig. 78).
IMPORTANT! DO NOT drop washers and bolts into the cabinet.
6. Move the fan onto the lift truck by one of the following methods: