Table 2 Preventive Maintenance Schedule

ProCore™
Edge
Component
Description
Output Cables
Three Output
Cable
Connectors
Cool-Air Intake
and Hot-Air
Exhaust Vents
ProCore™
Exterior
ProCore™
Interior
31241-03-01
Maintenance Verification/Action
Examine cables and replace any cable
that exhibits signs of damage
(splits, cracks, tears, exposed conductors,
etc.) or excessive wear
Examine connectors, and replace
any connector that exhibits signs of damage
(splits, cracks, exposed or pitted power
pins, etc.) or excessive wear.
Inspect the cool-air intake vents at the
system back and hot-air exhaust vents at
the system lower-front for any reduced
airflow or blockage. Remove any
airflow obstruction to ensure proper
system cooling.
Examine the charger exterior for signs of
damage or excessive wear. Repair or
replace any system that has been damaged
in such a way that conductors are exposed,
or the cabinet may contact
internal conductors.
Vacuum out dust from the charger interior,
using a vacuum designed for electronic
systems. Pay close attention to electronic
devices to prevent damage. It may be
necessary to vacuum out dust more
frequently if the unit is installed in a highly
dusty environment.
Page 54 of 68