Webasto ProCore Edge 9 Installation, Operation And Maintenance Manual page 66

Hide thumbs Also See for ProCore Edge 9:
Table of Contents

Advertisement

ProCore Edge North America
Message/
Name
Battery
Communication
Timeout
Battery
Connection
Issue
31241-03-01
Severity Description
Fault
Fault
Page 58 of 68
The battery
voltage is too
low (i.e., below
the operational
voltage limit)
to use on
this charger
The BMID
number of
battery cells
setting is
incorrect.
The
communication
with the battery
was lost
over the
communication
bus.
Battery
initialization
failed during
connection.
Webasto Charging Systems, Inc.
IOMM
Action(s)
Use a charger
that supports the
battery voltage.
Use the
ProCore™ App
BMID setup to
set the correct
number of
battery cells.
Check the
communication
wires.
Check the
battery
communications
wiring for
damage.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procore edge 15

Table of Contents