Webasto ProCore Edge 9 Installation, Operation And Maintenance Manual page 63

Hide thumbs Also See for ProCore Edge 9:
Table of Contents

Advertisement

IOMM
ProCore™
Edge
Component
Description
ProCore™
Interior
Harness
Connections
Check for
discoloration:
NEGATIVE
DC OUTPUT
POSITIVE
DC OUTPUT
DC Output
Fuse
Data Contacts
on Output
Connectors
Webasto Charging Systems, Inc.
Maintenance Verification/Action
Examine for signs of damage or wear in all
harness connections.
Examine the high-current path for signs of
discoloration; and replace any discolored
components, making sure to use the correct
torque on all fasteners.
Fuses do not require maintenance until
an overcurrent event causes them to open,
or they experience excessive heat due to
a loose connection.
The data contacts in the output cable
should last for a minimum of
5000 disconnection cycles.
Disconnections
per Day
4
7
9
13
25
ProCore Edge North America
Replace
Contacts Every
"X" Months
40
24
18
12
6
Page 55 of 68
Schedule
*
*
*
31241-03-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procore edge 15

Table of Contents