Fault
Message
AC POWER
LOW
AC POWER
PHASE
MODULE TYPE
ERR

3.8. Maintenance

3.8.1. Brush dust from the intake grill, on the bottom, every
six months.
3.8.2. Check the condition of the output cable and connectors
every month.
24407-W-03 Rev-01
Operations and Maintenance Manual
Possible Cause(s)
The utility AC
voltage is too low
for safe
charger operation.
The charger is not
receiving AC power
in all three phases.
The module has
failed and blown a
backplane fuse.
The power module
and cabinet
voltage settings do
not match.
Page 12 of 13 Webasto Charging Systems, Inc.
Solution(s)
Check the AC
input voltage.
Confirm that the utility
breaker has not tripped
on one of the phases.
Replace the power
module that caused the
fuse to blow,
and replace the
backplane fuses.
Install the correct
power module.