Table 1 Bare-Ended Signal Connections - Webasto ProCore Edge 9 Installation, Operation And Maintenance Manual

Hide thumbs Also See for ProCore Edge 9:
Table of Contents

Advertisement

IOMM
Table 1 describes the bare-ended signal connections
that can be connected to the charger via
this connector.
Connection Description
Pin 10
Pin 9
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
The connector can accept up to a 16-AWG wire.
CAUTION
Use only copper wires.
Webasto Charging Systems, Inc.

Table 1 Bare-ended Signal Connections

CAN1-L/DATA (RED)
CAN1-H/DIR (WHITE)
PILOT (GREEN)
PILOT RETURN (BLACK)
SWA and SWB (DCT pins 6 and 5, respectively)
are for an external pilot interlock connection.
These pins, in order to charge, must be shorted
either by a normally closed pilot interlock
connection or by a jumper. A jumper between
these pins is factory installed to ensure that the
unit operates when it reaches a destination.
Negative lead connecting and controlling the
24-VDC WATERING VALVE
Positive lead connecting the
24-VDC WATERING VALVE
Negative lead to the SPARE RELAY
Positive lead to the SPARE RELAY
ProCore Edge North America
Page 29 of 68
31241-03-01