Figure 3 Side-To-Side Charger Spacing With Dividers; Figure 4 Offset 45-Degree Angle Charger Installation - Webasto ProCore Edge 9 Installation, Operation And Maintenance Manual

Hide thumbs Also See for ProCore Edge 9:
Table of Contents

Advertisement

ProCore Edge North America
Side-to-Side Charger Spacing with Dividers
Place metal panels between chargers for closer spacing
(Figure 3). The minimum charger-to-divider spacing,
for standard installations, is 4 in. (10 cm). The divider dimensions
should be, at a minimum, 24" H × 20" W and 30" H × 20" W
(609.6 mm H × 508 mm W and 762 mm H × 508 mm W)
for 3- and 5-bay cabinets, respectively.

Figure 3 Side-to-Side Charger Spacing with Dividers

Offset (45-degree–Angle) Charger Installation
Chargers may be installed also at an offset 45-degree angle for
higher density installations (Figure 4).

Figure 4 Offset 45-degree Angle Charger Installation

31241-03-01
4 in. (10 cm)
Page 8 of 68